HMI supplier in China

Top rated HMI wholesale manufacturer: Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects. See even more details on switching power supply manufacturers.

Corresponding Functional Requirements: Gemerally, small plc have functions such as logic operation, timing and counting, which can be met for equipment that only needs to be controlled by switching quantity. For systems with switching control as the main and a small number of analog control, an enhanced plc with A/D and D/A conversion units and functions of addition and subtraction arithmetic operations and data transmission can be selected. For complex control, it is required to realized PID calculation, closed-loop control, communication networking and other functions, visual control scale and complexity, and choose mid-range or high-grade plc. However, medium and large PLC are more expensive and are generally used in large-scale process control and distributed control system.

Object-oriented principle: That is, according to the identity characteristics and work nature of the operator, design a human-machine interface that is compatible and friendly. According to their work needs, it is appropriate to display prompts, guidance and help information in pop-up windows, so as to improve the level of user interaction and efficiency. HMI, whether for the field controller or for the upper monitoring and management, the two are closely interconnected, they monitor and manage the field equipment objects are the same, so many field equipment parameters are shared between them and passed to each other. The standardized design of the human-machine interface should be the future development direction, because it really reflects the easy-to-configure, simple, and practical principles of the base, fully expressing the human-centered design concept. A variety of industrial control configuration software and programming tools provide powerful support for the production of a beautiful human-machine interface, and the larger and more complex the system, the more it can reflect its superiority.

It is good to choose a brand according to the needing of the customers or the market. But it is not for selecting a brand to decide, or more about to focus on its performance parameters, and to be used the functions achieved. Actually there is an attractive story behind the famous brand. So to choose a brand, try to achieve high practicality, to avoide waste one’s talent on a petty job. For example, Siemens, Mitsubishi, Proface, Panasonic brand…etc with a good performance, but before decision to select them, should consider, how many performance of HMI panel will be used for the project? Whether the cost paid matches the performance used on the project? See additional info on mochuan-drives.com.

Touch panel interface and PLC communication fail communication, needing check four factors: 1. Are the PLC parameters consistent with those in the project? 2. Are the communication lines connected according to the pins in the wiring diagram. 3. Is the COM port set in the project correct when connecting on the screen. 4. If it is confirmed that the parameters and wiring are OK, see whether it is the PLC program or the PLC address.

Multiple color of shell and panel cutout for selecting, it is more flexible to match different project to improve the overall aesthetics and practical. Suggestions and recommendations to our customers through over a decade field experience industry and industry solution through software and hardware, if you work with us. If require the special technology, special function, special size, special parameter, special color, shape or special performance of ihm, welcome contact us for ODM. Mochuan hmi panel manufacturers will be very seriously and give timely feedback.

There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.

The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.

In the wisdom of industry, electrical cabinet control equipment is suitable for electric facilities, chemical plants, mechanical plants, plant electrical control, network companies electrical control, site large electrical equipment control, etc., to provide convenient electrical management services for the majority of enterprises. Whether it is a small or large electrical cabinet control equipment, it can easily manage the whole company, the whole enterprise, the whole factory electrical equipment.

Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc.